INQUIRY
Leave Your Message
CH series intelligent PID thermostat temperature controllers

CH series intelligent PID thermostat temperature controllers

Features:  

* Standard autotuning

* Large LED screen display

* Heat/cool control

* Numerous control outputs

* ℃/℉

* Universal input

* Field-configurable thermocouples

* Operation is the same to CH series

    SPECIFICATIONS

    INPUT

    A) Thermocouple: K,J,E,T,R,S,B,U,L,N,PL2,W5Re/w26Re

    B) RTD: Pt100

    C) DC input: DC0-5V,DC1-5V,DC0-20mA*,DC4-20mA*

    * Requires a 250Ω resistor connected to the input terminal

    Input display accuracy: 0.3%±1 of the set value SV

    Sampling Time: 0.5 sec

     

    PV BIAS

    -1999~9999℃ or -199.9~999.9℃(temperature input)

    ±full span(voltage/current input)

     

    SETTING RANGE

    A) Setting range: same as input range

    B) Heat-side proportional band(P): 1 to span or 0.1 to span (ON/OFF action when P=0)

    C) Cool-side proportional band(Pc): 0 to 1000% of heat-side proportional band (heat/cool ON/OFF action when Pc=0)

    D) Integral time(I): 0 to 3600sec.(PD action when I=0)

    E) Derivative time(D): 0 to 3600sec.(PI action when D=0)

    F) Anti-reset windup(ARW): 1 to 100% of heat-side proportional band

    G)Deadband/overlap: -10 to 10℃(°F ) or -10.0 to 10.0℃(°F)

    H) Proportional cycle: 1 to 100 sec.

     

    CONTROL METHOD

    A) PID control with autotuning

    *Available for reverse and direct action (Specify when ordering)

    B) Heat/Cool PID control with autotuning (Specify when ordering)

    *Available for air and water cooling type

     

    CONTROL OUTPUT

    A) Relay output: 250V AC 5A (resistive load)

    B) Voltage pulse output: 0-12V DC (Load resistance: more than 600Ω)

    C) Current output: 4-20mA/DC 0-20mA/DC (Load resistance: less than 600Ω)

    0-10mA(Load resistance: 800Ω)

     

    TEMPERATURE ALARM

    A) Number of alarm: 2 points (Maximum)

    B) Alarm action: Deviation High,Low,High/Low,Band Process High,Low

    C) Alarm differential gap: 2℃(°F) or 2.0℃(°F) as standard.

     

    ALARM OUTPUT

    Relay output, Form A contact 250V AC 5A (resistive load)

     

    WARRANTY

    18 months

    Specifications

    Models Code
    CH102(48x48mm)
    CH402(48x96mm)
    CH702(72x72mm)         F 口口口-口  口*口  口-口  口

    CH902(96x96mm)         
    CH502(96x48mm)
    CH802(160x80mm)
    Control method PID control with AT(reverse action) F
    Input type See Range and Input Code Table 口口口
    Control
    output
    (OUT1)
    Relay contact output
    Voltage pulse output
    DC current output 4-20mA
    Triac trigger output
    Triac output
    M
    V
    8
    G
    T
    Control
    output
    (OUT2)
    Relay contact output
    Voltage pulse output
    DC currentoutput 4-20mA
    Triac output
    M
    V
    8
    T
    Alarm No alarm
    See Alarm Code Table

    N

    Communication No communication N
    IPXX No waterproofand dustproof N

    Note: No alarm function when OUT2 used for cooling

    POWER SUPPLY

    Power Supply
    100-240VAC
    24VAC
    24VDC

    ALARM CODE TABLE

    Code Type
    A Deviation High
    B Deviation Low
    C Deviation High - Low
    D Deviation Band
    E Deviation High with Hold
    F Deviation Low with Hold
    G Deviation High/Low with Hold
    H Process High
    J Process Low
    K Process High with Hold
    L Process Low with Hold
    R Loop break alarm(LBA)
    V SV  High alarm
    W SV  Low alarm

    RANGE AND INPUT CODE TABLE

    RTD

    Input Code Range
    PT100 D 01 -199.9-649.0℃
    D 02 -199.9-200.0℃
    D 05 -100.0-200.0℃
    D 08 0.0-200.0℃
    D 10 0.0-500.0℃

    VOLTAGE AND CURRENT

    Input Code Range
    DC0~5V 4 01 0.0~100.0
    DC1~5V 6 01 0.0~100.0
    DC0~20mA # 7 01 0.0~100.0
    DC4~20mA # 8 01 0.0~100.0

    # A resistor of 250Ω must be connected between input terminals.

    THERMOCOUPLE

    Input Code Range
    K K 01 0-200
    K 02 0-400
    K 03 0-600
    K 04 0-800℃
    K 05 0-1000℃
    K 06 0-1200℃
    K 07 0-1372℃
    J J 01 0-200℃
    J 02 0-400℃
    J 03 0-600℃
    J 04 0-800℃
    J 05 0-1000℃
    J 06 0-1200℃
    R 01 0-1600℃
    R 02 0-1769℃
    S 01 0-1600℃
    S 02 0-1769℃
    B 01 400-1800
    B 02 0-1820
    E E 04 0-800
    E 02 0-1000
    N N 01 0-1200
    N 02 0-1300
    T 01 -1999-400℃
    T 02 -199.9-100℃
    T 03 -100.0-200℃
    T 04 0.0-350
    W5Re/W26Re

    PL II
    W 01 0-2000
    W 02 0-2320
    A 01 0-1300
    A 02 0-1390
    A 03 0-1200

    1.Type R,S,B input: Accuracy is not guaranteed between 0 and 399°C.
    2.Type T input: Accuracy is not guaranteed between -199.9~+100.0°C.